Toxfree® ZH H07Z1-K (AS) the extra-flexible pre-wired LSZH

The halogen-free cables Toxfree® ZH H07Z1-K (AS) are pre-wired cables suitable for tap-offs, which are characterised by their extra flexibility as well as their extra sliding properties. In addition, they guarantee safety in the event of fire thanks to official recognition with the CPR regulation B2ca-s1a,d1,a1, the highest safety standard required by the European Union in the event of fire.

DESIGN:

1 – Conductor de cobre electrolítico flexible (clase 5).

2 – Polyolefin, halogen free and low smoke under fire conditions and extra slippery insulation.

TOXFREE ZH H07Z1-K AS

FOR A DOMESTIC INSTALLATION

Toxfree® ZH H07Z1-K (AS) halogen-free cables for branches meet all the requirements of ITC-BT 15 (Bonding installations. Individual branches). The individual branch supplies electricity to an individual user’s installation, a domestic installation, from the general supply line.

These cables include in their configuration the conductors used for power transmission (phases, brown, and neutral, blue) and the protection conductor (earth, yellow/green), as well as the control wire (red) joined in a single unwired bundle. The function of the earth wire is very important, since when faults occur in the electrical system, it diverts the energy and minimises the chances of electrocution occurring while the wiring is being handled.

EXTRA SLIPPERY AND HIGHLY FLEXIBLE CABLES

When we talk about Toxfree® ZH H07Z1-K (AS) cable, we are talking about an extra flexible, extra sliding pre-wiring. The installation of these pre-cables is very easy due to the extra sliding insulation and the high flexibility. By facilitating the work of the installer and simplifying the collection of materials, the cost of installations is reduced and labour costs are saved. This makes it a cable that is much sought after by installers, who see how their work becomes much more efficient.

In addition, it has the maximum CPR safety in case of fire, it has the B2ca-s1a,d1,a1 regulation, according to the European standard EN 50575. This feature makes it a cable especially suitable for installation, beyond domestic installations in homes as we have highlighted above, in public places, in industrial installations and under pipes.

toxfree H07Z1-K precableado

WHERE CAN I BUY THE TOXFREE® ZH H07Z1-K (AS) PRE-CABLE?

To buy this fire resistant cable on reels of various sizes, please see our sales conditions for Electrical Wholesalers and Distributors here. We can also put you in touch with your nearest Top Cable distributor.

Some of the most common electrical cable sections in immediate stock are as follows:

CableConductor cross-section
(mm2)
TOXFREE® H07Z1-K1×0,75
TOXFREE® H07Z1-K1×2,5
TOXFREE® H07Z1-K1×6
TOXFREE® H07Z1-K1×10
TOXFREE® H07Z1-K1×25
TOXFREE® H07Z1-K1×35
TOXFREE® H07Z1-K1×50
Most common H07Z1-K cable sections in immediate stock

If you need to consult additional technical aspects of this cable, such as its maximum admissible current or voltage drop, please contact us.